Part Number Hot Search : 
DTA144W 2500T FAN5063 VTX1100 1048172 C85FDBAB SF2090C F1020
Product Description
Full Text Search
 

To Download 3RHP2440E Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 3 Phase RHP - Hybrid Solid State Contactors
3 Phase Contactor
AC Input
40-50 Amp 280/600 VAC
ENT PATDING PEN
3 Phase Contactor
DC Input
40-50 Amp 120/240 VAC
ENT PATDING PEN
Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized
CONTROL SPECIFICATIONS
Control Voltage Suffix Coil Voltage Range Min. Turn-On Voltage Min. Turn-Off Voltage Coil Power Consumption, Inrush Coil Power Consumption, Sealed Coil Terminals
1
Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required DC logic compatible input Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized
CONTROL SPECIFICATIONS
Control Voltage Suffix Control Voltage Range Max. Reverse Voltage Min. Turn-On Voltage Min. Turn-Off Voltage Input Current Input Connector
1
E
20 - 26 VAC, 50/60 Hz 20 VAC 12 VAC 56 VA @ 24 VAC 6.6 VA @ 24 VAC 10 in lb (1.13 Nm)
1
F
G
100 - 130 VAC, 50/60 Hz 208 - 240 VAC, 50/60 Hz 100 VAC 208 VAC 24 VAC 48 VAC 56 VA @ 120 VAC 56 VA @ 220 VAC 6.6 VA @ 120 VAC 6.6 VA @ 220 VAC 10 in lb (1.13 Nm) 10 in lb (1.13 Nm)
D5
4.5 - 5.5 VDC -5.5 VDC 4.5 VDC 1 VDC 12mA @ 5 VDC 5.31 in lb (0.6 Nm)
1
D12
10 - 15 VDC -15.5 VDC 9.5 VDC 2 VDC 12mA @ 12 VDC 5.31 in lb (0.6 Nm)
D24
22 - 27 VDC -27.5 VDC 9.5 VDC 2 VDC 12mA @ 24 VDC 5.31 in lb (0.6 Nm)
OUTPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS 28
3
Voltage suffix Operating Voltage (50/60Hz) Maximum Off-State Leakage Current per channel Load Current suffix Maximum Load Current per Phase @ 40C Power terminals / wire range Screw torque requirements
2
60
48 - 600 VAC 0.06 mA @ 480 VAC
24 - 280 VAC 0.05 mA @ 240 VAC
Voltage suffix Operating Voltage (50/60Hz) Maximum Off-State Leakage Current per channel Load Current suffix Maximum Load Current per Phase @ 40C Power terminals / wire range Screw torque requirements
12
3
24
208 - 240 VAC 0.06 mA @ 240 VAC
100 - 120 VAC 0.05 mA @ 120 VAC
40
40 A Resistive Dual quick connect and Binder head screws / AWG#14 - AWG#8 18 in lbs (2.1 Nm)
50
50 A Resistive Dual quick connect and Box lugs / AWG#14 - AWG#6 25 in lbs (2.9 Nm)
40
2
50
40 A Resistive 50 A Resistive Dual quick connect and Binder Dual quick connect and Box head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6 18 in lbs (2.1 Nm) 25 in lbs (2.9 Nm)
GENERAL SPECIFICATIONS
1
GENERAL SPECIFICATIONS
4000 VAC 2500 VAC Three Normally Open
4
1
Input to Output Dielectric Isolation. Input/Output to Ground Dielectric Isolation. Contacts (Double Break )
3
Input to Output Dielectric Isolation Input/Output to Ground Dielectric Isolation Contacts (Double Break) 3 Ambient Operating Temperature Range
4
4000 VAC 2500 VAC Three Normally Open -20C to 75C -40C to 100C 16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz 30 operations per min > 2 Million operations 540 grs (1.19 lb)
Ambient Operating Temperature Range Ambient Storage Temperature Range
-20C to 75C -40C to 100C 16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz 30 operations per min > 2 Million operations 540 grs (1.19 lb)
Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute Lifetime @ Rated Load Current, 40C ambient temp, 30 operations/min, Rated Vcontrol Weight (typical)
1 2 3 4
Ambient Storage Temperature Range Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute Lifetime @ Rated Load Current, 40C ambient temp, 30 operations/min, Rated Vcontrol Weight (typical)
1 2 3 4
Specificationts @ 25C unless otherwise noted. See Derating Curves for additional operational conditions. The RHP includes a Solid-State Relay. Therefore, the output is never completely open. The RHP includes an overtemperature protection for the Solid-State Module.
Specificationts @ 25C unless otherwise noted. See Derating Curves for additional operational conditions. The RHP includes a Solid-State Relay. Therefore, the output is never completely open. The RHP includes an overtemperature protection for the Solid-State Module.
Part Number Nomenclature
SERIES
Load Current 40: 40 Amps 50: 50 Amps
Derating Curves
3RHPXX40XX
55
3RHPXX50XX
Load Current, Amps rms
3 RHP
Three Phase Device
12
40 D5
Nominal Coil /Control Voltage D5: 5 VDC D12: 12 VDC D24: 24 VDC E: 24 VAC F: 120 VAC G: 220 VAC
Load Current, Amps rms
45
50 45 40 35 30
40
Operating Voltage VAC 50/60 Hz 12: 120 V 1-phase 24: 240 V 3-phase or 1-phase 28: 280 V 3-phase 60: 600 V 3-phase
35
Power lead size
AWG # 6 AWG # 8
Power lead size AWG # 6 AWG # 8
30
Safe Operating Area
25
Safe Operating Area
25 20 25 35 45 55 65 75 25 35 45 55 65 75
20
Ambient Temperature, C
Ambient Temperature, C
Typical Electrical Connection for 3 Phase Applications
(For output voltage options 24, 28, 60)
5
3 Phase RHP - Hybrid Solid State Contactors
AC Input/Control Voltage (E, F, G input versions)
I L3
HYBRID SOLID STATE CONTACTOR
5L3 3L2
VLL
6T3 4T2 2T1 I L1
120/240 VAC Single Phase Operating Voltage
HYBRID SOLID STATE CONTACTOR
3 Phase AC Operating Voltage
~ ~ ~
AC Input/Control Voltage (E, F, G input versions)
3O Load
~
Line Line
5L3 3L2 1L1
I L3
-+
I L2 R1 I L1
R2
-+
Neutral
DC Input/Control Voltage (D5, D12, D24 input versions)
1L1 I L1
DC Input/Control Voltage (D5, D12, D24 input versions)
IL1 = (IL2 + IL3) Rated current
AC Input/Control Voltage (E, F, G input versions)
DO NOT apply any AC voltage to contactor coil connections, for DC versions only.
Optional Electrical Connections for Single Phase Applications 6
(For output voltage options 12, 24, 28, 60)
AC Input/Control Voltage (E, F, G input versions)
120/240 VAC Single Phase Operating Voltage 6T3=NC
-+
Line
120/240 VAC Single Phase Operating Voltage
Neutral
~
3L2 1L1
HYBRID SOLID STATE CONTACTOR
5L3=NC
~
Neutral
HYBRID SOLID STATE CONTACTOR
5L3 3L2 1L1
7
I L3
-+
I L2 R2 NC R1
I L1 R1
DC Input/Control Voltage (D5, D12, D24 input versions)
IL2 Rated current IL3 Rated current IL2 + IL3 > Rated current
DC Input/Control Voltage (D5, D12, D24 input versions)
5 6 7
IL1 Rated current
Match VLL to voltage suffixes 28 & 60 for options E, F & G and 12 & 24 for options DX. The single phase supply voltage must be wired to terminal 1L1 and 3L2 for proper single phase operation. In applications switching two single phase loads (R1 and R2) where the combined load current exceeds the contactor's rating (40 or 50 Amps) the return/neutral lead must not be wired through the contactor (see above drawing).


▲Up To Search▲   

 
Price & Availability of 3RHP2440E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .